Rvr-1 Single Phase Automatic Step Voltage Regulator for Substation

Rvr-1 Single Phase Automatic Step Voltage Regulator for Substation

RVR-1 Solitary Section Computerized Stage Voltage Regulator for Substation 

CZPT

The RVR-one type feeder automatic voltage regulator is truly a single phase oil immersed automobile-transformer with RVR controller and accumulating sampling of voltage ¤t signal, on load tap charger managing system to obtain gird far more successful from change the load character by boost and decrease the voltage.

So This RVR is a transformer geared up with on load tap charger with RVR controller sampling voltage and recent knowledge and on load tap charger actions from present transformer and voltage transformer and limit switches.

Primary Features

+The RVR-1 regulate distribution line voltages from ten% elevate (improve) to ten% reduce (buck) in thirty-two methods of approximately 5/8% each and every. Voltage ratings are CZPT from 2400 volts (sixty kV BIL) to 34,five hundred volts (two hundred kV BIL) for 60 Hz and 50 Hz programs.

+With RVR type Wise controller, a self-produced technological innovation, GPRS/GSM, Blue-tooth.

+With self-safety LOCK-OUT features: Line fault, Overload, OverCurrent, Beneath-voltage

+With adjustable voltage datum and action scope restrict, phase draw delay, data placing.
 

CZPT Features

• Position indicator with Add-AMP adjustment

• Handle box

• Tap changer with motor and energy offer

• Oil drain valve with sampling device

• Computerized strain relief gadget

• Lifting lugs

• Nameplates

• Large-creep porcelain bushings

• Oil sight gauge

• Pole mounting brackets

• Handle cupboard with detachable front panel

• Conformally coated circuit boards

• MOV-type exterior series arresters

Define

 

1,Terminals block
two,High-creep porcelain bushings
3,Radiator group
four,Strain relief device
five,Lifting lugs
6,Nameplates
seven,Ground stud
8,Terminal box
nine,The tap placement indicator
10,Pole mounting brackets
11,SEL Sensible controller
twelve,Oil drain valve with sampling unit

Principal Datas
 

Voltage(kV)
BIL(kV)
Load Existing
(Amperes)
kVA
two.5 kV
60 kV BIL
two hundred
300
400
five hundred
668
a thousand
1332
1665
50
75
a hundred
one hundred twenty five
167
250
333
416
five. kV
75 kV BIL
100
one hundred fifty
two hundred
250
334
five hundred
668
833
fifty
seventy five
100
125
167
250
333
416
7.62 kV
95 kV BIL
100
one hundred fifty
219
328
438
546
656
875
1093
seventy six
114
167
250
333
416
five hundred
667
833
thirteen.8 kV
ninety five kV BIL
one hundred
one hundred fifty
200
300
four hundred
483
604
138
207
276
414
552
667
833
19.92 kV
150 kV BIL
50
100
167
two hundred
335
418
502
one hundred
two hundred
333
four hundred
667
833
1000

 

Round Shape and Square Shape 

                             Control Panel                                                                            Place Indicator     
 


 

Spherical Shape 

 

Sq. Form

Generation Line 

 

Rvr-1 Single Phase Automatic Step Voltage Regulator for Substation