Issue
Place of operation    Indoors, no direct sunlight, free of charge from dust, corrosive gases, flammable gases, oil mist, water vapor, h2o drop and salt, and so forth.
Altitude    0~2000m
De-fee 1% for every single 100m when the altitude is earlier mentioned one thousand meters
Ambient temperature    -10ºC~40ºC. The rated output recent must be de-rated one% for each and every 1ºC when the ambient temperature is 40ºC~50ºC
Relative humidity    5~95%, no condensation
Vibration    Less than 5.9m/s2 (.6g)
Storage temperature    -40ºC~+70ºC

Funtions:
Parameter copy, parameter backup,
frequent DC bus, totally free switchover between two motors’ parameters,
flexible parameter displayed & concealed, various grasp & auxiliary command and switchover,
dependable speed look for started,
a assortment of Accel/Decel curves programmable, automated correction of analog, contracting brake management,
sixteen-step pace manage programmable (2 steps help versatile frequency command),
wobble frequency handle, set length handle, rely operate, three faults recorded,
Above excitation brake, more than voltage stall safety programmable,
underneath voltage stall safety programmable, restart on electricity reduction, skip frequency, frequency binding,
four sorts of Accel/Decel time, motor thermal security, versatile admirer management, process PID manage, easy PLC, multi-useful crucial programmable, droop control,
asynchronous and synchronous motor parameter identification, area-weakening management,
large-precision torque handle, V/f divided control, torque management at sensor-significantly less vector management,
torque handle at shut-loop vector management, two encoder signal inputs (assist incremental, UVW hybrid and resolver, and many others.),
Flexible deceleration ratio manage, zero servo, motor spindle orientation, basic feed CZPT management, pulse prepare situation control

Attribute:

asynchronous motors and long term magnet synchronous motors precisely with the optimized algorithm. 
Sizzling pluggable and detachable handle panel
Many options are CZPT for port expansion, practical mix and update.
with four manage modes: V/f, SVC1, SVC2 and VC
 two varieties of flying start, monitoring the pace of motor and attain smooth begin.
 the function of Cycle-by-Cycle present limit. 
Short lifeless time between CZPT and reverse
protect the bulk of industrial sectors, specific in demanding ones that require specific velocity control, torque manage, pressure management, quick response and so forth. 

 

AC Variable Frequency Drive Three Single Phase 690V VFD